Discharge door
Discharge door is slow or does not fully open
Possible causes
- 1
The door seal is swollen or torn.
- 2
Air pressure to the cylinder is low.
Check & fix
- Check the plant air pressure.
- Look for a torn seal or a stone in the door track.
- Cycle the door with the mixer empty.